336 Excavator

  • Specs Summary

C175-16 Tier 4 Final

The C175-16 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications, and match your power standards. Producing reliable power from 2500 to 3000 ekW (3100 ekW without fan) in 60 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and to accept 100 percent rated load in one step. Our C175-16 generator sets range from low fuel consumption systems to EPA Stationary Emergency (Tier 2). Leading innovation means some models offer emissions reduced by up to 90 percent — it's technology that has benefits well beyond todays regulations. Seismic certification is also available for select models, maintaining your power after unexpected disturbances. Our integrated control system, including ATS and switchgear, ensures a consistent power supply and connection to your fleet through on-site and remote monitoring options. Our EMCP 4 control panel provides expandable controller options, with management and diagnostic tools, and a user-friendly interface. It's not just quality that matters but customization, choose from a broad range of accessories and bolt-on system expansion attachments. Find flexible packaging to fit unique spatial requirements and environmental conditions. Our C175-16 generator sets are developed for such prerequisites, so that you can meet your specific power needs. For added safety select from one of the UL 2200 and CSA certified package options.

Standard Equipment

Air Inlet System

  • Air Cleaner; 4 x single element canister with service indicator(s).

Control Panel

  • EMCP4.3 controls including emergency stop button
  • EMCP4.3 controller including: 24-volt DC operation - Environmental sealed front face - Text alarm/event descriptions
  • Warning/shutdown with common LED indication of shutdowns with indicating lights for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant level (requires optional coolant sensor)
  • Generator mounted - rear facing
  • Controls: Speed adjust - Auto/start/stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test
  • True RMS AC metering, 3-phase, +/-0.25% accuracy
  • Digital indication for: RPM - DC volts - Operating hours - Coolant temperature - Volts (L-L & L-N) - Frequency (Hz) - Amps (per phase & average) - Power Factor (per phase & average) - kW (per phase, average & percent) - kVA (per phase, average & percent) - kVAr (per phase, average & percent) - kW-hr (total) - kVAr-hr (total)
  • Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High Coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level Over / Under voltage (27/59) - Over / Under frequency (81 o/u) - Reverse power (kW) (32) - Reverse reactive power (kVAr) (32RV) - Overcurrent (50/51)
  • Communications: Customer data link (Modbus RTU) - Accessory module data link - Serial annunciator module data link - 6 programmable digital inputs - 4 programmable relay outputs (Form A) - 2 programmable relay outputs (Form C) - 2 programmable digital outputs - 12 programmable digital inputs - 16 programmable digital outputs - 3 programmable analog inputs - 3 programmable analog outputs - 2 programmable PWM outputs
  • Local annunciator option

Cooling System

  • SCAC cooling
  • Radiator group shipped loose.
  • Fan and belt guards
  • Coolant drain line and valves
  • Coolant sensor - (2 x shipped loose: 1/4-18 and 1/2-14 NPTF).

Exhaust System

  • Insulated CEM
  • CEM dosing module
  • CEM dosing module features: Air filter - DEF filter - 120 VAC - Anti-freeze protection
  • Harness from dosing module to CEM
  • Air and heated DEF lines from dosing module to CEM
  • Dry exhaust manifold
  • Flanged faced outlets at CEM in (21.2") and out (25")

Fuel System

  • Primary fuel filter water / fuel water separator
  • 10 Micron spin on type
  • 3 Filters, shipped loose - can be mounted on frame rails (Requires dealer provided flex)
  • Secondary / tertiary fuel filters
  • 4 Micron Spin On Type
  • 3 Filters, engine mounted

Generator and Attachments

  • 3 Phase brushless, salient pole
  • 6 lead
  • IEC platinum stator RTDs (.00385 temperature coefficient)
  • Caterpillar's digital voltage regulator (CDVR) includes: Reactive droop capability - 3-Phase voltage sensing - KVAR / PF modes - RFI suppression - Min / Max exciter limiter - Exciter diode monitor
  • 1800 Frame generators (LV/MV)
  • Form wound
  • NEMA Class H insulation
  • Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • (LV) Bus bar connections, top / center mounted, top cable entry 60 Hz models: NEMA standard hole pattern
  • (MV)Bus bar connections, right side extension box, bottom cable entry: - 60 Hz models: NEMA standard hole pattern
  • 3000 Frame generators (MV/HV)
  • Form wound
  • Permanent magnet
  • Anti condensation space heater
  • NEMA Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
  • Right side extension box, bottom cable entry

Governing System

  • ADEM A4
  • Redundant shutdown (Overspeed protection through a duplicate speed sensing system)

Lube System

  • Lubricating oil
  • Gear type lube oil pump
  • Integral lube oil cooler
  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Fumes disposal
  • Prelube - required with prime and continuous; optional with standby

Mounting System

  • Rails - Engine / Generator
  • Rubber anti-vibration mounts (shipped loose).
  • Dual 24-volt electric starting motors
  • Batteries and battery rack w/cables
  • Battery disconnect switch

Service Instructions

  • Two PM Inspections

General

  • Paint - Caterpillar yellow with high gloss black rails & radiator
  • RH Service (except oil filter service 60 Hz models: left hand service
  • Flywheel and flywheel housing-SAE No. 00
  • SAE standard rotation
  • *For HV EMCP4.3 control panel: Includes wall mount control panel, shipped loose, for customer mounting and 7.5 meter interconnect harness.
  • * For HV applications, customer to provide 120V secondary sensing, 5A secondary current sensing and harness between package and EMCP4.3 (drawing provided). CDVR is installed in wall mount.

Optional Equipment

Air Inlet System

  • Single stage air cleaner

Control Panels

  • EMCP 4.3
  • EMCP 4.4 requires 1800 frame low voltage packages
  • E-Stop - Only for use with 3000 frame generators and EMCP4.3
  • Load share module
  • EMCP mounting location - LV / MV -- requires 1800 frame generator
  • Customer AC-DC connection mounting location - LV / MV
  • Load share governor / auxiliary plate and auxiliary box (LV)
  • Remote speed adjust
  • Annunciator modules
  • Customer interface options
  • Generator temperature monitoring
  • Modbus monitoring of packages
  • Vandal proof panel door

Cooling System

  • Package mounted radiator
  • Remote radiators
  • SCAC circuits
  • Fuel cooler

Exhaust

  • Exhaust collectors / manifold

Fuel System

  • Primary fuel filter

General

  • Paint - colors (other than Caterpillar yellow) or high performance paints
  • US aid emblem

Generator and Attachments

  • 480 Volts, Generators (LV) 60 Hz, 3 phase, 1800 rpm, FW, PM, 6 leads, pitch = 0.6667 - 1800 frame
  • 480 Volts, Generators (MV) 60 Hz, 3 phase, 1800 rpm, FW, PM, 6 leads, pitch = 0.6667 -- 1800, 3000 frame
  • Space heater kit
  • Thermostat for space heater
  • Differential current transformers (DCT): - 5, 9 and 15 kV class DCTs

Instrumentation

  • Pyrometer and thermocouples
  • Harness - ECM interconnect

Lube System

  • Lube oil heater
  • Oil pan drain valve
  • Standard sump oil pan
  • Lubricating oil
  • Electric prelube pump
  • Oil filters

Crankcase Systems

  • Explosion relief valves

Mounting System

  • Rubber anti-vibration mounts
  • Spring-type linear vibration isolators
  • IBC vibration isolators - shipped loose

Power Connections

  • Center post busbars (LV) connections
  • Side / Rear monted busbars (LV)
  • Cable entry options (LV)
  • Control packating (LV) - Enclosures
  • Power connection covers
  • Optional package mounted circuit breakers (LV)
  • 4000 Amp, 3 Pole, UL-100% Rated Circuit Breakers
  • 4000 Amp, 3 Pole, IEC-Rated Circuit Breakers
  • 5000 Amp, 3 Pole, UL-100% Rated Circuit Breakers
  • 5000 Amp, 3 Pole, IEC-Rated Circuit Breakers
  • Circuit Breaker Harness
  • MV Power Connection Options: 1800 Frame generator side / rear mounted busbars - Left hand MV nema busbar - Right hand MV nema busbar
  • Cable entry options - 1800 frame (MV)
  • Neutral ground - (MV)
  • Masterpack breaker connections

Service Tools - Barring Groups

  • Engine group
  • Group manual
  • Engine air powered
  • Control GP-airpowered group

Special Tests / Reports

  • Generator test report
  • PGS test report @ 1.0 power factor
  • PGS test report @ 0.8 power factor
  • Standard genset torsional nibration analysis (TVA) report
  • Custom genset TVA report
  • Fuel consumption test
  • Standard engine test charge

Starting/Charging

  • 24 Volt power distribution box
  • 24 Volt electric starting motor
  • Air starting motor
  • Covers - starter locations
  • 24 Volt battery set - dry
  • Heavy duty battery set with rack
  • 35 and 50 Amp battery chargers
  • Jacket water heaters
  • Jacket water heater wiring groups