NC Machinery Logo

336 Excavator

  • Specs Summary
  • Maximum Continuous Rating
    ( )
  • Voltage
  • Gas Standby Rating
  • Fuel Type
    ( )

Gas Generator CG132B-16

The Cat CG132B family of gas engines are perfectly tailored to the challenges of the power plant in an age of global value chains.<br>
<br>
Highly efficient with low operating and installation costs and lubricant consumption, the Cat CG132B gas generator set is available with outputs from 400kW to 800kW and comes with the Total Plant and Energy Management (TPEM) system.
  • Engine Model ( )
  • RPM ( )
  • Width 70 in (1780 mm)
  • Frequency ( )
  • Displacement 2135.8 in (35 l)
  • Bore 5.2 in (132 mm)
  • Length 165 in (4200 mm)
  • Stroke 6.3 in (160 mm)
  • Maximum Continuous Rating ( )
  • Maximum Standby Rating ( )
  • Maximum Electrical Efficiency ( )
  • Aspiration ( )
  • Fuel Type ( )
  • Height 85 in (2150 mm)

Standard Equipment

Air Inlet

  • Turbocharger with a water-cooled bearing case for all cylinder
  • One-element single-stage air cleaner with enclosure and sevice indicator

Control Panels

  • TPEM (Total Plant & Energy Management System)

Cooling

  • ANSI/DN customer flange connections for JW inlet and outlet
  • Flange connections for JW inlet and outlet
  • Jacket water and SCAC thermostats
  • Electrical jacket water and aftercooler coolant pump
  • flange connections for JW inlet and outlet
  • ANSI/DN customer flange connections for JW inlet and outlet
  • Cat flanges on SCAC circuit

Exhaust

  • Exhaust waste gate for the CG132B-16
  • Closed crankcase ventilation system
  • PEARL/Low resistence exhaust system

Fuel system

  • Electronic fuel metering valve
  • Pre-chamber spark plugs
  • Electronic fuel metering valve
  • Independently controlled cylinder monitoring and ignition system
  • Independently controlled cylinder monitoring and ignition system
  • Pre-chamber spark plugs

Generator

  • grid code generator
  • Reactive droop
  • Anti-condensation space heater
  • 3-phase sensing and KVAR/PF control
  • closed-coupled generator result in no torque transmission to the base frame
  • Busbar connections
  • Reactive droop
  • Anti-condensation space heater
  • 3-phase sensing and KVAR/PF control
  • Winding temperature detectors
  • Winding temperature detectors
  • Busbar connections

Starting/Charging

  • Battery disconnect switch
  • 24V starting motors
  • Battery disconnect switch

General

  • Crankshaft vibration damper and guard
  • Crankshaft vibration damper and guard

Optional Equipment

Air Inlet

  • Air cleaner with precleaner
  • Mounting stand

Cooling

  • CHP skid
  • CHP skid